Septic Tank Pumping Frequency Calculator
Years between pumpings, from the pumping chart of Kansas State University Research and Extension.
2.6years between pumpings
About every 2 years and 7 months for a 1,000-gallon tank and 4 people.
Septic tank pumping frequency chart
| Tank size (gal) | People in the home | ||||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
| 500 | 5.8 | 2.6 | 1.5 | 1.0 | 0.4 | 0.2 | – |
| 750 | 9.1 | 4.2 | 2.6 | 1.8 | 1.0 | 0.6 | 0.3 |
| 900 | 11.0 | 5.2 | 3.3 | 2.3 | 1.3 | 0.8 | 0.5 |
| 1,000 | 12.4 | 5.9 | 3.7 | 2.6 | 1.5 | 1.0 | 0.7 |
| 1,250 | 15.6 | 7.5 | 4.8 | 3.4 | 2.0 | 1.4 | 1.0 |
| 1,500 | 18.9 | 9.1 | 5.9 | 4.2 | 2.6 | 1.8 | 1.3 |
| 1,750 | 22.1 | 10.7 | 6.9 | 5.0 | 3.1 | 2.2 | 1.6 |
| 2,000 | 25.4 | 12.4 | 8.0 | 5.9 | 3.7 | 2.6 | 2.0 |
| 2,250 | 28.6 | 14.0 | 9.1 | 6.7 | 4.2 | 3.0 | 2.3 |
| 2,500 | 31.9 | 15.6 | 10.2 | 7.5 | 4.8 | 4.0 | 2.6 |
About these figures
Table 1 of Septic Tank Maintenance: A Key to Longer Septic System Life (MF-947, August 2010) by Judith M. Willingham, Kansas State University Research and Extension; read October 29, 2026. The publication · Data source
From the publication: “The frequencies were calculated to provide a minimum of 24 hours of wastewater detention assuming 50 percent digestion of the retained solids, 50 gallons of sewage per person per day and no garbage disposal. If a garbage disposal is used, the time between pumpings should be decreased by about one-third.”